Commercial design using autodesk revit 2019












Revit does not currently have a way to specify whether the connection uses the subfeed lugs. The Lugs field for the upstream panel will be set to Double. To create a connection using top lugs, enable the Feed Through Lugs and SubFeed Lugs parameters in the upstream panel, then set the Connection Type for the downstream panel to Feed Through Lugs. The Lugs field for the upstream panel will be set to Feed Through. To create a connection using feed through lugs, enable the Feed Through Lugs parameter in the upstream panel, then set the Connection Type for the downstream panel to Feed Through Lugs. The isolated ground can be set in the family using the Family Edit command and on instances using the Instance Edit command.įeed Through Lugs: The new feed through lugs feature in Revit 2020 works with the one-line diagram created by Design Master Electrical. Any circuits that include a device with an isolated ground will include an isolated ground in the wire callout. The arc-flash calculation has been updated to use IEEE Std 1584-2018.Īn isolated ground wire can be included on branch circuit devices. Finally, the branch circuit make-up length can also be set for each individual branch circuit. The branch circuit make-up length can be set for each circuit on a piece of distribution equipment.

commercial design using autodesk revit 2019

A default branch circuit make-up length can be set for the project. Wire length make-up is additional length added to calculated distances between devices.įeeder Length Make-up: Each piece of distribution equipment can have a separate feeder length make-up assigned.īranch Circuit Length Make-up: Branch circuits can now have make-up included in the calculated length. The additional make-up settings provide greater control of calculated wire lengths. The Feeder Make-up option has been expanded from a single project value. The following is a list of new and updated features in Design Master Electrical RT 1.4. We realize you have actual billable work to do and 30 days can go by fast. Contact us if you need additional time to try the software.

#Commercial design using autodesk revit 2019 software

The software is fully functioning during that time. Note: This app uses a custom installer (and not the standard App Store installer). Arc-flash warning labels can be printed to be put on devices in the field.ĭesign Master Electrical RT is available for purchase on our website for $400 / year. An arc-flash schedule can be created that displays the calculated values. Feeders that exceed the maximum 3% voltage drop allowed can be easily resized.Īrc-Flash Calculations: Arc-flash calculations are performed at each piece of electrical equipment. Voltage Drop Calculations: The voltage drop is calculated between each piece of electrical equipment. The calculated fault current can be used to set the AIC rating for the device.

commercial design using autodesk revit 2019

You have complete control of the breaker and wire size and can override it when necessary.įault Calculations: Available fault current is calculated for each piece of electrical equipment. You have complete control of the chosen feeder size and can override it when necessary.īranch Circuit Sizing: Branch circuit breakers and wire sizes are sized automatically based upon the connected load. Keep your one-line diagram synchronized with the rest of your project as your design changes.įeeder Sizing: Feeders are size automatically based upon the upstream overcurrent protection for a piece of electrical equipment. Customize the graphics to match your existing one-line diagram. One-Line Riser Diagrams: Automatically generate one-line riser diagrams from your Revit model.

commercial design using autodesk revit 2019

Design Master Electrical RT adds electrical calculations to Autodesk® Revit® MEP.